Combustion error
ApplianceWhat it means
Several combustion errors occur within 24 hours
Likely causes
- Low ionisation current
- Air in gas supply
- Gas valve not fully opened
- Incorrect gas supply pressure
- Gas valve unit malfunction
- Blocked air supply inlet or flue gas outlet
- Recirculation of flue gases
Where to start
- Vent the gas supply to remove air
- Check that the gas valve is fully opened
- Check the gas supply pressure
The full answer, free
- 11 more checks in order
- The readings and component tests from the manual
- How to put it right, step by step
- The manual page for this fault (page 80), right under the answer
Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.
From the Baxi manual for the Quinta Ace. Check the model on the data plate before you order parts.