Baxi Quinta Ace fault E.01.12
Return higher flow
ApplianceWhat it means
Return temperature has a higher temperature value than the flow temperature
Likely causes
- Flow and return reversed
- Bad connection
- Water circulation in wrong direction
- Incorrectly fitted sensor
- Malfunctioning sensor
- Faulty sensor
Where to start
- Check the wiring and connectors
- Check the circulation (direction, pump, valves)
- Check that the sensor has been correctly fitted
The full answer, free
- 4 more checks in order
- How to put it right, step by step
- The manual page for this fault (page 79), right under the answer
Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.
From the Baxi manual for the Quinta Ace. Check the model on the data plate before you order parts.