Baxi Quinta Ace fault E.04.12

False flame

Appliance

What it means

False flame detected before burner start

Likely causes

  1. Burner remains very hot
  2. Ionisation current measured but no flame should be present
  3. Faulty gas valve
  4. Faulty ignition transformer

Where to start

  1. Set the O2 if burner remains very hot
  2. Check the ionisation/ignition electrode

The full answer, free

  • How to put it right, step by step
  • The manual page for this fault (page 81), right under the answer

Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.

From the Baxi manual for the Quinta Ace. Check the model on the data plate before you order parts.

Other Baxi Quinta Ace fault codes