Baxi Quinta Ace fault H.01.21

Dhw temp GradLevel3

Appliance

What it means

Maximum DHW Temperature Gradient Level3 Exceeded - the flow temperature has risen too fast

Likely causes

  1. Flow/circulation issue
  2. Pump malfunction

Where to start

  1. Check the flow (direction, pump, valves)
  2. Check that the pump is operating correctly

The full answer, free

  • How to put it right, step by step
  • The manual page for this fault (page 77), right under the answer

Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.

From the Baxi manual for the Quinta Ace. Check the model on the data plate before you order parts.

Other Baxi Quinta Ace fault codes