Baxi Quinta Ace fault H.01.08

CH temp grad level3

Appliance

What it means

Maximum CH temperature gradient level3 exceeded - maximum heat exchanger temperature increase has been exceeded

Likely causes

  1. No flow or insufficient flow
  2. Sensor error

Where to start

  1. Check the circulation (direction, pump, valves)
  2. Check the water pressure
  3. Check the cleanliness of the heat exchanger

The full answer, free

  • 6 more checks in order
  • How to put it right, step by step
  • The manual page for this fault (page 76), right under the answer

Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.

From the Baxi manual for the Quinta Ace. Check the model on the data plate before you order parts.