Baxi Baxi 600/800/Assure System 2 and 600 Combi 2 platform fault H.03.02

Temporary flame loss

Gas boiler

What it means

Flame signal temporarily lost, possibly due to electrode, gas supply, or flue issues

Likely causes

  1. Electrode connection/wiring issue
  2. Poor electrode condition
  3. Gas supply pressure issue
  4. Incorrect gas valve calibration
  5. Flue gas pipe/terminal issue
  6. Ionisation current below 4 µA
  7. Electrode worn
  8. Electrode distances out of range

Where to start

  1. Check the electrode connection and wiring
  2. Check the condition of the electrode
  3. Check the gas supply pressure