Baxi Baxi 600/800/Assure System 2 and 600 Combi 2 platform fault GM044-12

Shutdown caused by flame value being too low

Gas boiler

What it means

Shutdown caused by insufficient flame signal/current detected.

Likely causes

  1. Weak or unstable flame
  2. Faulty flame sensing electrode
  3. Poor gas supply/pressure
  4. Dirty or degraded ionisation electrode

Where to start

  1. Check actual flame current measured (GM008)
  2. Inspect ionisation electrode condition
  3. Check gas supply pressure

The full answer, free

  • The readings and component tests from the manual
  • How to put it right, step by step
  • The manual page for this fault (page 59), right under the answer

Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.