Baxi Baxi 600/800/Assure System 2 and 600 Combi 2 platform fault E.04.12

Ignition failure for monitoring parasitic flame

Gas boiler

What it means

Ignition failure for monitoring parasitic flame

Likely causes

  1. Ground circuit fault
  2. Power supply voltage issue
  3. Ionisation current below 4 µA
  4. Electrode worn
  5. Electrode distances out of range

Where to start

  1. Check the ground circuit
  2. Check the power supply voltage
  3. Check GM003 Flame detected status

The full answer, free

  • 9 more checks in order
  • The readings and component tests from the manual
  • How to put it right, step by step
  • The manual page for this fault (page 77), right under the answer

Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.

From the Baxi manual for the Baxi 600/800/Assure System 2 and 600 Combi 2 platform. Check the model on the data plate before you order parts.