Baxi Baxi 600/800/Assure System 2 and 600 Combi 2 platform fault E.01.20

Maximum flue gas temperature reached

Gas boiler

What it means

Maximum flue gas temperature reached, indicating exchanger blockage on flue gas side

Likely causes

  1. Exchanger on flue gas side blocked
  2. Carbon/soot buildup in heat exchanger
  3. Cracked or damaged burner
  4. Worn burner flange gasket
  5. Damaged front insulation panel

Where to start

  1. Check the cleanliness of the exchanger
  2. Isolate the unit from the power supply (disconnect the boiler from the main power supply)
  3. Cut off the gas supply to the boiler

The full answer, free

  • 15 more checks in order
  • The readings and component tests from the manual
  • How to put it right, step by step
  • The manual page for this fault (page 76), right under the answer

Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.

From the Baxi manual for the Baxi 600/800/Assure System 2 and 600 Combi 2 platform. Check the model on the data plate before you order parts.

Other Baxi Baxi 600/800/Assure System 2 and 600 Combi 2 platform fault codes