Baxi Baxi 600/800/Assure System 2 and 600 Combi 2 platform fault GM044-9

Temperature difference between flow and return too great

Gas boiler

What it means

Shutdown caused by excessive temperature differential between flow and return sensors, indicating poor circulation.

Likely causes

  1. Low water flow through heat exchanger
  2. Pump fault or blockage
  3. Air in system

Where to start

  1. Check pump operation and speed (AM010)
  2. Check system for air/blockage
  3. Check that the boiler pump venting valve is working

The full answer, free

  • 1 more check in order
  • How to put it right, step by step
  • The manual page for this fault (page 59), right under the answer

Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.

From the Baxi manual for the Baxi 600/800/Assure System 2 and 600 Combi 2 platform. Check the model on the data plate before you order parts.