Vokera Pinnacle Combi fault E041

Low water pressure (temporary fault)

Gas boiler

What it means

Temporary fault indicating the boiler is not working properly due to low water pressure. Operation required within 10 minutes of message appearing, otherwise the anomaly becomes definitive (E040).

Likely causes

  1. System water pressure dropped significantly
  2. Water leak in heating system
  3. Failure to top up system after FIL warning

Where to start

  1. Check Water pressure reading for system pressure
  2. Check system pressure on LCD display or gauge on underside of appliance
  3. Check pressure transducer operation if burner/pump/fan de-activate on low pressure

The full answer, free

  • 1 more check in order
  • The readings and component tests from the manual
  • How to put it right, step by step
  • The manual page for this fault (page 6), right under the answer

Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.

From the Vokera manual for the Pinnacle Combi. Check the model on the data plate before you order parts.