Viessmann Vitodens 100-W fault 67

Ionisation current lies outside the permissible range

Gas boiler

What it means

Burner enters a fault state because the ionisation current reading is outside the permissible range.

Likely causes

  1. Gas supply issue (gas pressure and gas flow switch)
  2. Blocked inlet strainer

Where to start

  1. Check gas supply (gas pressure and gas flow switch)
  2. Check gas solenoid valve and inlet strainer

The full answer, free

  • The manual page for this fault (page 70), right under the answer

Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.