Viessmann Vitodens 100-W fault 348

Gas modulation valve

Gas boiler

What it means

Burner in a fault state related to the gas modulation valve, which may be caused by multiple heat generators sharing a flue system without correct configuration, or flue restrictions.

Likely causes

  1. Gas modulation valve fault
  2. Multiple heat generators on common flue system not configured correctly
  3. Restricted flue system flow
  4. Simultaneous operation of boiler and air-extracting appliances
  5. Negative pressure created by extractor hoods, extractors, air conditioning units, or central vacuum cleaning systems

Where to start

  1. If several heat generators are connected to a common flue system: Check whether "Multiple connections" is set in the commissioning assistant.
  2. Check the flue system for unrestricted flow.
  3. Turn off the ON/OFF switch.

The full answer, free

  • 17 more checks in order
  • The readings and component tests from the manual
  • How to put it right, step by step
  • The manual page for this fault (page 74), right under the answer

Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.

From the Viessmann manual for the Vitodens 100-W. Check the model on the data plate before you order parts.