Viessmann Vitodens 100-W fault 176
Condensate backup in the heat cell
Gas boilerWhat it means
Burner in a fault state due to condensate backup within the heat cell, potentially causing water damage to internal components.
Likely causes
- Condensate backup in the heat cell
- Flue system leak causing flue gas recirculation
- Incorrect gas flow pressure
Where to start
- Remove condensate backup.
- Inspect insulation blocks, electrodes and burner gauze assembly for damage.
- Check the flue system for tightness (flue gas recirculation).
The full answer, free
- 1 more check in order
- How to put it right, step by step
- The manual page for this fault (page 73), right under the answer
Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.
From the Viessmann manual for the Vitodens 100-W. Check the model on the data plate before you order parts.
Other Viessmann Vitodens 100-W fault codes
- 100PlusBus voltage error
- 12Short circuit, collector temperature sensor
- 161HBMU heat management unit data memory access fault
- 162Processor low voltage
- 163Checksum error, data memory access, HBMU heat management unit
- 346Ionisation current calibration error
- 347Flue gas recirculation
- 348Gas modulation valve
- 349Air mass rate flow not detected correctly in fan unit
- 350Ionisation current lies outside the permissible range
- 351Ionisation current lies outside the permissible range
- 352Combustion CO limit exceeded
- 355Analogue signal reference check: flame signal already present at burner start
- 359No ignition spark, burner in fault state
- 361Flame signal not present or insufficient at burner start
- 364Internal fault, burner in fault state
- 368Gas pressure switch fault, burner locked out
- 369Flame lost immediately after flame formation (during safety time)
- 371Fan speed too low
- 372Repeated flame loss during calibration
- 373Heat transfer too low during calibration, temperature limiter shut down
- 374Burner restarts, stabilisation conditions for pre-calibration not met
- 375Ionisation current calibration not performed
- 376Ionisation current differential not plausible