Viessmann Vitodens 100-W fault 368

Gas pressure switch fault, burner locked out

Gas boiler

What it means

Burner locked out due to a gas pressure switch fault; the forced ventilation time has expired.

Likely causes

  1. Gas pressure switch fault
  2. Insufficient gas supply pressure
  3. Forced ventilation time expired

Where to start

  1. Check gas supply (gas pressure).
  2. If installed, check gas pressure switch for correct function.
  3. If necessary, disconnect the gas pressure switch and check whether the burner starts.

The full answer, free

  • The manual page for this fault (page 76), right under the answer

Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.

From the Viessmann manual for the Vitodens 100-W. Check the model on the data plate before you order parts.

Other Viessmann Vitodens 100-W fault codes