Midea M-Thermal Arctic HT R290 Mono fault E0

Water flow failure

Heat pump

What it means

Water flow failure detected before pump activation. Triggered by 5 consecutive no-water detection failures in a row before pump on, or 10 consecutive E8 occurrences in a row during running-water detection after pump on.

Likely causes

  1. No water flow before the pump starts (e.g. external pump still running/interfering)
  2. Incorrect dip switch configuration for pump type
  3. Water flow restriction or blockage
  4. Air in water system
  5. Flow switch leak due to faulty sealing ring
  6. External pump starts before internal pump (PUMPI) starts
  7. The water flow in the pipe is not consistent with arrow on the flow switch
  8. Flow switch FS plug (CN8) is not connected properly
  9. Water flow switch rake mechanically damaged
  10. Flow switch not installed properly
  11. Water flow switch mechanically damaged (rake does not trigger contact closure)
  12. Pump stalling due to impeller obstruction
  13. Water pump internal failure despite correct wiring
  14. Water pump malfunction indicated by abnormal indicator light status
  15. Water pump leak due to faulty sealing ring
  16. Water pump connection is correct, the water pump icon on the User Interface is lit, while no indicator lights on water pump is lit
  17. Pump idling
  18. Pump idling due to insufficient water/air in circuit

Where to start

  1. Locate water flow switch, water pump, air purge valve, water inlet and water outlet using this layout when diagnosing E0/E8 faults
  2. Verify DIP switch S2 positions 3/4 match installed pump type
  3. Locate CN28 PUMP connector to check power supply to water pump

The full answer, free

  • 32 more checks in order
  • The readings and component tests from the manual
  • How to put it right, step by step
  • The manual page for this fault (page 95), right under the answer

Safety: Isolate the outdoor unit and any backup heater, and give the inverter capacitors time to discharge before you open the electrics. Anything on the refrigerant circuit needs F-gas certification.

From the Midea manual for the M-Thermal Arctic HT R290 Mono. Check the model on the data plate before you order parts.

Other Midea M-Thermal Arctic HT R290 Mono fault codes