Joule Victorum fault 81
No temp diff across evaporator
Heat pumpWhat it means
No temperature differential detected across the evaporator. This is a temporary blocking fault - the Heat Pump automatically restarts after 1 hour.
Likely causes
- Fan not operating correctly
- Possible blockage in the duct system
- Kitchen ceiling valve installed too close to kitchen extractor fan
Where to start
- Check fan operation
- Check for possible blockage in the duct system
- Navigate to Settings icon (second Settings tile) > Adjust air valves? setting