Grant Euroflame fault 5

Boiler operating on overheat thermostat

Oil boiler

What it means

Boiler trips on the overheat thermostat, indicating excessive water temperature, often due to lack of circulation.

Likely causes

  1. Faulty boiler thermostat
  2. No circulation
  3. Faulty circulating pump
  4. Air lock in system
  5. Motor/pump fault
  6. Electrode/ignition fault
  7. Control box fault
  8. Oil pump fault
  9. Solenoid valve/coil fault
  10. Nozzle/fuel contamination
  11. Combustion air/head setting fault
  12. Photocell fault
  13. Balanced flue recirculation
  14. Boiler or flue blockage
  15. Incorrect diffuser position causing poor flame pattern or combustion issues
  16. Contaminated oil pump filter restricting fuel flow
  17. Air lock in pump
  18. Pump running dry

Where to start

  1. Check circulating pump
  2. Check for air lock
  3. Burner motor runs? NO -> Check L & N to control box -> if fail check boiler controls

The full answer, free

  • 22 more checks in order
  • The readings and component tests from the manual
  • How to put it right, step by step
  • The manual page for this fault (page 43), right under the answer

Safety: Isolate oil and power before you touch the burner. Do a combustion test after any burner adjustment or part change. OFTEC (or equivalent) work only.

From the Grant manual for the Euroflame. Check the model on the data plate before you order parts.