Glow-worm Energy Combi fault S.53

Product in waiting period / operating block due to water deficiency (flow/return...

Gas boiler

What it means

Status indicating the product is in a waiting period or operating block due to excessive flow/return temperature spread, indicating water deficiency in the circuit.

Likely causes

  1. Low water flow through heat exchanger
  2. Pump fault or closed valves restricting flow

Where to start

  1. Check system water flow rate
  2. Check pump operation
  3. Check the silicone hose connection (1) between the pump's automatic air vent and the hydraulic console

The full answer, free

  • The readings and component tests from the manual
  • How to put it right, step by step
  • The manual page for this fault (page 51), right under the answer

Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.

From the Glow-worm manual for the Energy Combi. Check the model on the data plate before you order parts.