Glow-worm Energy Combi fault F.62

Fault: gas valve switch-off control

Gas boiler

What it means

Fault in gas valve switch-off control, delayed switch-off detected

Likely causes

  1. Delayed switch-off of gas valve assembly
  2. Delayed extinguishing of flame signal
  3. Gas valve assembly leaking
  4. Electronics defective

Where to start

  1. Compare measured heat output against rated effective output range for the given flow/return temperature to confirm correct modulation
  2. Switch off the product via the main switch
  3. Close the gas stopcock

The full answer, free

  • 11 more checks in order
  • The readings and component tests from the manual
  • How to put it right, step by step
  • The manual page for this fault (page 52), right under the answer

Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.

From the Glow-worm manual for the Energy Combi. Check the model on the data plate before you order parts.