Glow-worm Energy Combi fault F.00

Flow temperature sensor fault

Gas boiler

What it means

Fault relating to the flow temperature sensor (NTC) circuit.

Likely causes

  1. NTC plug not plugged in or has come loose
  2. Multiple plug on the PCB not plugged in correctly
  3. Interruption in cable harness
  4. NTC sensor defective

Where to start

  1. Check NTC plug connection
  2. Check multiple plug on PCB
  3. Check cable harness continuity

The full answer, free

  • 1 more check in order
  • How to put it right, step by step
  • The manual page for this fault (page 51), right under the answer

Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.

From the Glow-worm manual for the Energy Combi. Check the model on the data plate before you order parts.