Worcester Bosch Greenstar i Combi ErP fault EA227

No ionisation after ignition

Gas boiler
Free account: 6 more checks, the readings and the manual page (page 66). No card needed.See the full EA227 answer

What it means

Ignition/ionisation fault: no flame (ionisation) signal was detected after ignition.

Likely causes

  1. Incorrect dynamic gas pressure.
  2. Flue restriction.
  3. Incorrect gas-air ratio.
  4. Ignition unit connector fault, damage or wear.
  5. Gas valve fault.
  6. Contaminated appliance.
  7. Blocked condensate pipes.

Where to start

  1. Check the dynamic gas pressure.
  2. Check the flue system for restrictions.
  3. Check the gas-air ratio (if possible).

The full answer, free

  • 6 more checks in order
  • The readings and component tests from the manual
  • How to put it right, step by step
  • The manual page for this fault (page 66), right under the answer

Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.

Full EA227 fix, readings and manual page. Free.See the full answer

From the Worcester Bosch manual for the Greenstar i Combi ErP. Check the model on the data plate before you order parts.

Other Worcester Bosch Greenstar i Combi ErP fault codes