Worcester Bosch Greenstar i Combi ErP fault E9276
Primary flow temperature exceeded 95°C
Gas boilerFree account: 1 more check, the readings and the manual page (page 65). No card needed.See the full E9276 answer
What it means
Flow sensor fault: the primary flow temperature has gone above 95°C.
Likely causes
- Low primary system water pressure.
- Air in the system.
- Poor circulation within the heating system.
- Faulty pump wiring or operation.
- Faulty flow temperature sensor.
Where to start
- Check the primary system water pressure.
- Check for air in the system.
- Check circulation within the heating system.
The full answer, free
- 1 more check in order
- The readings and component tests from the manual
- How to put it right, step by step
- The manual page for this fault (page 65), right under the answer
Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.
Full E9276 fix, readings and manual page. Free.See the full answer
From the Worcester Bosch manual for the Greenstar i Combi ErP. Check the model on the data plate before you order parts.
Other Worcester Bosch Greenstar i Combi ErP fault codes
- 9U233Control box or HCM defective or loose
- C1264Fan stopped during operation
- C4237Control box or HCM defective
- C6215Fan speed too high
- C6216Fan speed too low
- C7214Fan does not run during start-up
- C7217Fan stopped during operation
- E2222Flow temperature sensor shorted
- E2223Flow temperature sensor disconnected
- E2350Flow temperature sensor shorted
- E2351Flow temperature sensor disconnected
- EA227No ionisation after ignition
- EA229Loss of ionisation during operation
- EA261HCM potentially defective
- F0238Gas valve or control box error
- F0239Control box or HCM defective
- FA306Ionisation after gas valve closed
- H09Pump communications error
- H29Outdoor sensor defect