Worcester Bosch Greenstar CDi Classic System ErP fault F7
Flame detected even though appliance switched off
Gas boilerWhat it means
The control system has detected a flame signal while the appliance is switched off, indicating a possible false flame signal or component fault.
Likely causes
- Faulty electrode assembly
- Wet/damp PCB
- Blocked flue
Where to start
- Check electrode assembly
- Dry PCB
- Check flue is clear
The full answer, free
- How to put it right, step by step
- The manual page for this fault (page 52), right under the answer
Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.
From the Worcester Bosch manual for the Greenstar CDi Classic System ErP. Check the model on the data plate before you order parts.