Worcester Bosch Greenstar CDi Classic System ErP fault E9
Safety temp. limiter in CH flow has tripped
Gas boilerWhat it means
The safety temperature limiter in the central heating flow circuit has tripped, indicating an over-temperature condition.
Likely causes
- Low system pressure
- Faulty safety temp. limiter
- Faulty pump operation
- Blown fuse on PCB
- Air in appliance
Where to start
- Check system pressure
- Check safety temp. limiters
- Check pump operation
The full answer, free
- 2 more checks in order
- How to put it right, step by step
- The manual page for this fault (page 52), right under the answer