Worcester Bosch Greenstar 4000 Combi fault 2965

Flow temperature too high

Gas boiler

What it means

Flow temperature detected as too high, potentially due to lack of water flow or system not filled.

Likely causes

  1. No water flow because CH system is closed
  2. No water flow because pump is not operating correctly

Where to start

  1. Check for air locks in the system
  2. Check isolation valves

The full answer, free

  • How to put it right, step by step
  • The manual page for this fault (page 78), right under the answer

Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.

From the Worcester Bosch manual for the Greenstar 4000 Combi. Check the model on the data plate before you order parts.