Worcester Bosch Greenstar 4000 Combi fault 1010

No communication via EMS BUS connection

Gas boiler
Free account: 4 more checks, the readings and the manual page (page 75). No card needed.See the full 1010 answer

What it means

No communication over the EMS BUS to the controls. The manual leaves the category blank.

Likely causes

  1. Loose grey ribbon low voltage connection.
  2. Key connections plugged in wrongly.
  3. Key not pushed fully home.
  4. Flat room control batteries.
  5. Missing bridging links at LR and 230 V out.
  6. Incorrect EMS BUS voltage to the remote control.
  7. 230 V wiring interfering with the BUS connections.
  8. Faulty control unit.

Where to start

  1. Check the grey ribbon (low voltage connection) on the far right of the PCB (page 75).
  2. If a Key control is used, check its connections (black, white, red, green) are in the right positions on the PCB, under the installer cover on the far right, leaving one space to the BUS connection (page 75).
  3. Check the Key is pushed fully home (page 75).

The full answer, free

  • 4 more checks in order
  • The readings and component tests from the manual
  • How to put it right, step by step
  • The manual page for this fault (page 75), right under the answer

Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.