Vokera Vibe fault A41

Fill the system (transitional)

Gas boiler

What it means

Transitional fault shown when pressure value falls below the 0.3 bar safety value; displayed for a transitory time of 10 minutes. If fault persists after this time, fault code A40 appears.

Likely causes

  1. System pressure fallen below 0.3 bar safety value
  2. Low system water pressure below 0.3 bar
  3. Leak in heating system
  4. Faulty seal or joint

Where to start

  1. Monitor pressure for 10 minutes to see if it self-corrects or escalates to A40
  2. If fault persists beyond 10 minutes, A40 will appear
  3. Open the filling valve slowly until water is heard entering the system

The full answer, free

  • 4 more checks in order
  • The readings and component tests from the manual
  • How to put it right, step by step
  • The manual page for this fault (page 28), right under the answer

Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.

From the Vokera manual for the Vibe. Check the model on the data plate before you order parts.