Vaillant VU 446/5-5 / VU 606/5-5 fault F.85

Flow and return temperature sensors installed incorrectly (inverted)

Gas boiler

What it means

Fault indicating the flow and return NTC sensors have been swapped or installed on the same/incorrect pipe.

Likely causes

  1. Flow/return NTC installed on the same/incorrect pipe
  2. Defective heating flow or return temperature sensor

Where to start

  1. Check that the flow and return NTCs have been installed on the correct pipe.
  2. Pull out the heating flow (4) and return temperature sensor (3)
  3. Remove the heating flow (1) and return plug (2)

The full answer, free

  • How to put it right, step by step
  • The manual page for this fault (page 63), right under the answer

Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.

From the Vaillant manual for the VU 446/5-5 / VU 606/5-5. Check the model on the data plate before you order parts.