Vaillant VU 446/5-5 / VU 606/5-5 fault F.03

Cylinder temperature sensor interruption

Gas boiler

What it means

Cylinder temperature sensor interruption detected.

Likely causes

  1. NTC sensor defective
  2. NTC plug loose/not plugged in
  3. Connection to cylinder electronics defective
  4. Defective heating flow or return temperature sensor

Where to start

  1. Check the NTC plug and plug connection.
  2. Check the connection to the cylinder electronics.
  3. Pull out the heating flow (4) and return temperature sensor (3)

The full answer, free

  • 1 more check in order
  • How to put it right, step by step
  • The manual page for this fault (page 60), right under the answer

Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.

From the Vaillant manual for the VU 446/5-5 / VU 606/5-5. Check the model on the data plate before you order parts.