Triton Novel fault 7
Pump is noisy
Electric showerWhat it means
The shower pump is producing excessive noise during operation.
Likely causes
- Air lock in pump
- Faulty pump
- Supply pipework undersized for pump flow rate
- Air drawn into hot supply from vent pipe
Where to start
- Check for air lock in pump
- Verify hot water supply temperature does not exceed 65°C maximum
- Confirm stored hot water temperature at 60°C for hard water scale minimisation