Triton Novel fault 2

Water too cold

Electric shower

What it means

Shower output water temperature is too cold.

Likely causes

  1. Hot inlet filter blocked or check valve sticking
  2. Not enough hot water flowing through shower
  3. Pipework rising above cistern water level causing air locks
  4. Decrease in ambient cold water temperature
  5. No hot water in the storage cylinder
  6. Hot water supply blocked or otherwise cut off

Where to start

  1. Inspect hot inlet filter and check valve
  2. Check hot water flow rate through shower
  3. Remove single retaining screw from centre of filter cap (fig.30)

The full answer, free

  • 4 more checks in order
  • The readings and component tests from the manual
  • How to put it right, step by step
  • The manual page for this fault (page 20), right under the answer

Safety: Isolate at the double pole isolator and the consumer unit, and prove dead before the cover comes off. Electrical work to BS 7671 (UK) or I.S. 10101 (Ireland).

From the Triton manual for the Novel. Check the model on the data plate before you order parts.