Samsung Gen 6 fault 122

Indoor unit eva in sensor (open/short)

Heat pump

What it means

Indoor unit evaporator inlet pipe sensor detected as open or shorted.

Likely causes

  1. Faulty indoor unit pipe sensor
  2. Faulty connection at PCB connector CN41

Where to start

  1. Check indoor unit pipe sensor
  2. Check indoor PCB connector CN41 (White)

The full answer, free

  • How to put it right, step by step
  • The manual page for this fault (page 52), right under the answer

Safety: Isolate the outdoor unit and any backup heater, and give the inverter capacitors time to discharge before you open the electrics. Anything on the refrigerant circuit needs F-gas certification.

From the Samsung manual for the Gen 6. Check the model on the data plate before you order parts.

Other Samsung Gen 6 fault codes