Riello NXHM fault P0

Low pressure switch protection

Heat pump

What it means

Low pressure switch has tripped, indicating insufficient refrigerant pressure in the system.

Likely causes

  1. System is lack of refrigerant volume
  2. Electrical expansion valve locked or winding connector loose

Where to start

  1. Check refrigerant charge volume
  2. Tap the expansion valve body and plug in/plug off the connector several times to verify valve operation

The full answer, free

  • How to put it right, step by step
  • The manual page for this fault (page 67), right under the answer

Safety: Isolate the heat pump and any backup heater, and give the inverter capacitors time to discharge before you open the electrics. Anything on the refrigerant circuit needs F-gas certification.

From the Riello manual for the NXHM. Check the model on the data plate before you order parts.