Riello NXHM fault EA
Discharge temperature sensor (tp) error
Heat pumpWhat it means
Fault with the compressor discharge temperature sensor Tp (note: listed remedy text matches communication fault wording, likely a table formatting error in the source manual).
Likely causes
- Wire doesn't connect between main control board PCB B and main control board of hydraulic module
- Communication wire sequence is not right
- High magnetic field or high power interference
- Inlet water temperature too low
- Ambient temperature too low causing target leaving water temperature to be too high
- T5 (DHW tank temperature) too low or ambient too low causing target T5 too high
- Rapid temperature change during initial heating of underfloor heating screed
Where to start
- Connect the wire
- Reconnect the wire in the right sequence
- Check for nearby interference sources
The full answer, free
- 4 more checks in order
- The readings and component tests from the manual
- How to put it right, step by step
- The manual page for this fault (page 66), right under the answer
Safety: Isolate the heat pump and any backup heater, and give the inverter capacitors time to discharge before you open the electrics. Anything on the refrigerant circuit needs F-gas certification.
From the Riello manual for the NXHM. Check the model on the data plate before you order parts.
Other Riello NXHM fault codes
- BHPED PCB failure
- C7Transducer module temperature too high protection
- E0Water flow fault (after 3 times E8)
- E1Phase loss or neutral wire and live wire connected reversely (three phase unit only)
- E2Communication fault between controller and hydraulic module
- E3Final outlet water temp. sensor (T1) fault
- E4Water tank temp. sensor (T5) fault
- E5Condenser outlet refrigerant temperature sensor (T3) error
- E6Ambient temperature sensor (T4) error
- E7Buffer tank up temp. sensor (Tbt1) fault
- E8Water flow failure
- E9Suction temperature sensor (th) error
- EBSolar temp. sensor (tsolar) fault
- ECBuffer tank low temp. sensor (Tbt2) fault
- EDInlet water temp. sensor (Tw_in) malfunction
- EEHydraulic module EEprom failure
- F1Low DC generatrix voltage protection
- H0Communication fault between main board PCB B and main control board of hydraulic...
- H1Communication error between inverter module PCB A and main control board PCB B
- H2Refrigerant liquid temp. sensor (T2) fault
- H3Refrigerant gas temp. sensor (T2B) fault
- H5Room temp. sensor (ta) fault
- H6The DC fan failure
- H7Voltage protection