Riello NXHM fault H9

Outlet water for zone 2 temp. sensor (Tw2) fault

Heat pump

What it means

Fault with the zone 2 outlet water temperature sensor Tw2.

Likely causes

  1. Sensor resistance out of range
  2. Tw2 sensor connector loosened
  3. Tw2 sensor connector wet or has water ingress
  4. Tw2 sensor failure

Where to start

  1. Check the resistance of the sensor
  2. Check if Tw2 sensor connector is loosened
  3. Check if connector is wet or has water in it

The full answer, free

  • How to put it right, step by step
  • The manual page for this fault (page 65), right under the answer

Safety: Isolate the heat pump and any backup heater, and give the inverter capacitors time to discharge before you open the electrics. Anything on the refrigerant circuit needs F-gas certification.

From the Riello manual for the NXHM. Check the model on the data plate before you order parts.