Grundfos STP 2 fault 4C
The pump runs continuously (float stuck in flow switch)
Shower pumpWhat it means
The float in the flow switch is stuck in the up (on) position, causing continuous running.
Likely causes
- The float in the flow switch is stuck in the up (on) position
- Low flow rates from cistern filling causing frequent pump cycling
- Entrapped air causing airlocks in supply pipe
- Air not thoroughly purged from system
- Air trapped in pump
- Outlet positioned below mains inlet causing air ingress
- Non-return valve fitted incorrectly in inlet pipe causing restricted flow or pump damage
- Pipes routed under floor causing air traps
- Direct mains connection causing pressure issues or pump damage
- Shared supply pipe causing air ingress or reduced flow
- Missing surrey flange causing air in hot water supply
- Blocked strainers common on initial pump installation or new buildings due to jointing compounds, tapes, flux and debris flushed through system
- Leak causing loss of tank air pressure
- Solder joint heat damaging plastic pump components
- Air pockets from incorrectly routed pipework
- Additional outlet fittings on inlet pipework causing incorrect flow switch operation
- Debris ingress into pump causing blockage or damage if strainer omitted
- Mechanical strain on pump from misaligned pipework
- Mechanical stress on pump from rigid pipe connection
Where to start
- Check flow switch for correct operation
- Check for debris in the flow switch
- Pump will run for a few seconds to recharge tanks
The full answer, free
- 38 more checks in order
- The readings and component tests from the manual
- How to put it right, step by step
- The manual page for this fault (page 14), right under the answer
Safety: Isolate power and water, and prove dead before you open or test the pump.
From the Grundfos manual for the STP 2. Check the model on the data plate before you order parts.
Other Grundfos STP 2 fault codes
- 1Pompa çalıştırılamıyor (positive displacement pumps)
- 10Hortum bağlantısında sızıntı var (universal head pumps)
- 1AThe pump fails to start (power supply switched off)
- 1BThe pump fails to start (fuses blown)
- 1CThe pump fails to start (thermal protection tripped)
- 1DThe pump fails to start (non-vertical outlet ports)
- 1EThe pump fails to start (insufficient water flow)
- 2Pompa çalışıyor fakat su basmıyor (positive displacement pumps)
- 2FThe pump runs but delivers no water (isolating valves closed)
- 2GThe pump runs but delivers no water (strainers blocked)
- 3Duştan gelen debi düşüyor (positive displacement pumps)
- 3AThe flow from the shower drops (strainers blocked)
- 4Pompa sürekli olarak çalışıyor (positive displacement pumps)
- 4DThe pump runs continuously (flow switch or reed switch faulty/incorrectly set)
- 5Pompada darbe görülüyor (positive displacement pumps)
- 5AThe pump pulses (other taps causing momentary start)
- 6Su sıcaklığı sabit değil veya pompa gürültülü çalışıyor (positive displacement pumps)
- 6BUnstable water temperature or noisy pump (too high water temperature)
- 7Pompa gürültülü çalışıyor (positive displacement pumps)
- 7ANoisy pump (vibration through mounting surface)
- 8Hortum bağlantısında sızıntı var (positive displacement pumps)
- 8AHose connection leaking (loose hose connection)
- 9Pompa gürültülü çalışıyor (universal head pumps)