Grant Aerona R32 fault A4

Protective action against excess current AC current detection

Heat pump

What it means

Protective shutdown due to excess AC current, caused by unreasonable operation under/overload, drop in power voltage, or momentary power stop.

Likely causes

  1. Blockage of air inlet & outlet
  2. Excess refrigerant gas
  3. Drop of power voltage
  4. Momentary power stop (lightning)

Where to start

  1. Check the place of installation (blockage of air inlet & outlet)
  2. Check the excess gas
  3. Check the power voltage (230V)

The full answer, free

  • The readings and component tests from the manual
  • How to put it right, step by step
  • The manual page for this fault (page 55), right under the answer

Safety: Isolate the outdoor unit and any backup heater, and give the inverter capacitors time to discharge before you open the electrics. Anything on the refrigerant circuit needs F-gas certification.

From the Grant manual for the Aerona R32. Check the model on the data plate before you order parts.