Glow worm Ultracom 2 fault S.53
Waiting cycle: temperature differential between heating flow and return too high
Gas boilerFree account: 12 more checks, the readings and the manual page (page 33). No card needed.See the full S.53 answer
What it means
Waiting cycle triggered because the temperature differential between heating flow and return is too high. If ΔT > 30, forcing to Pmin.
Likely causes
- Poor circulation
- Pump fault or blocked system
- Air in system
- Restricted flow causing excessive differential temperature
Where to start
- Check pump operation and flow rate
- Check for air in the system
- Check for blockages or restrictions in the heating circuit
The full answer, free
- 12 more checks in order
- The readings and component tests from the manual
- How to put it right, step by step
- The manual page for this fault (page 33), right under the answer
Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.
Full S.53 fix, readings and manual page. Free.See the full answer
From the Glow worm manual for the Ultracom 2. Check the model on the data plate before you order parts.
Other Glow worm Ultracom 2 fault codes
- F28Appliance fails to ignite due to insufficient gas flow, incorrect gas valve...
- F29Flame signal is lost while the burner is operating, caused by gas supply or ignition...
- F68Flame signal is fluctuating, caused by insufficient gas flow, incorrect gas valve...
- F76Thermal fuse dry fire protection triggered
- F77Fault in the gas valve motor caused by a defective gas valve or condensate pump
- F84Flow and return heating temperature sensors are inverted, disconnected, or defective
- F86Floor heating contact is open or sensor is disconnected/defective
- S.54Waiting cycle: lack of water / temperature rise too high
- S.98Test temperature sensors for heating flow and return, or appliance fault