Glow worm Ultracom 2 fault F68
Flame signal is fluctuating, caused by insufficient gas flow, incorrect gas valve...
Gas boilerFree account: 1 more check and the manual page (page 37). No card needed.See the full F68 answer
What it means
Flame signal is fluctuating, caused by insufficient gas flow, incorrect gas valve adjustment or defective ignition components.
Likely causes
- No return gas / Insufficient gas flow
- Gas valve incorrectly adjusted
- Defective firing electrode and flame control / Defective igniter unit
Where to start
- Check the return gas circuit (gas valve open).
- Observe the flame picture and check the CO2 setting.
- Check the igniter unit connections.
The full answer, free
- 1 more check in order
- How to put it right, step by step
- The manual page for this fault (page 37), right under the answer
Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.
Full F68 fix, readings and manual page. Free.See the full answer
From the Glow worm manual for the Ultracom 2. Check the model on the data plate before you order parts.
Other Glow worm Ultracom 2 fault codes
- F28Appliance fails to ignite due to insufficient gas flow, incorrect gas valve...
- F29Flame signal is lost while the burner is operating, caused by gas supply or ignition...
- F76Thermal fuse dry fire protection triggered
- F77Fault in the gas valve motor caused by a defective gas valve or condensate pump
- F84Flow and return heating temperature sensors are inverted, disconnected, or defective
- F86Floor heating contact is open or sensor is disconnected/defective
- S.53Waiting cycle: temperature differential between heating flow and return too high
- S.54Waiting cycle: lack of water / temperature rise too high
- S.98Test temperature sensors for heating flow and return, or appliance fault