Vokera Vision Plus Combi fault E090
Flue gas probe fault / overtemperature
Gas boilerFree account: 12 more checks, the readings and the manual page (page 43). No card needed.See the full E090 answer
What it means
Covers two conditions: flue gas probe fault (transitional) and flue gas probe overtemperature (definitive).
Likely causes
- Flue gas probe failure
- Flue gas probe overtemperature condition
- Flue gas probe fault
- Flue components not correctly assembled, fixed or supported
- Flue or flue terminal obstructed
- Leaking seals around appliance burner, internal flue seals, door or case seals
- Combustion products mixing with inlet air due to flue integrity failure
Where to start
- Set boiler to operate at maximum rate (full load) in accordance with section 7.3 and allow combustion to stabilise
- Insert analyser probe into air inlet sampling point and check: Is O2 ≥ 20.6% and CO2 < 0.2%?; if NO, verify flue integrity: check flue components are correctly assembled, fixed and supported as per boiler/flue instructions, and check flue and flue terminal are not obstructed
- Re-check: Is O2 ≥ 20.6% and CO2 < 0.2%? If still NO, turn off appliance and call Vokera's technical helpline for advice; appliance must not be commissioned until problems are resolved
The full answer, free
- 12 more checks in order
- The readings and component tests from the manual
- How to put it right, step by step
- The manual page for this fault (page 43), right under the answer