Vokera Vibe Max fault A80

Return probe fault / return probe overtemperature / return-flow sensor differential

Gas boiler
Free account: the manual page (page 28). No card needed.See the full A80 answer

What it means

Combined code covering three alarm conditions: return probe fault (transitional), return probe overtemperature (definitive), and return-flow sensor differential fault (definitive).

Likely causes

  1. Return probe fault
  2. Overtemperature condition at return probe
  3. Excessive differential between return and flow sensor readings - possible poor circulation
  4. Faulty return probe

Where to start

  1. Check return probe wiring and resistance
  2. Check for overtemperature condition at return probe
  3. Compare return and flow sensor readings for abnormal differential

The full answer, free

  • How to put it right, step by step
  • The manual page for this fault (page 28), right under the answer

Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.

Full A80 fix, readings and manual page. Free.See the full answer

From the Vokera manual for the Vibe Max. Check the model on the data plate before you order parts.