Triton T90SR fault 6

Shower performance drops, indicated by a gradual reduction in water flow

Electric shower

What it means

Gradual reduction in water flow over time, indicating water starvation to the unit.

Likely causes

  1. Blocked filter
  2. Blocked or air-locked water supply pipe

Where to start

  1. Check the filter is not blocked - isolate the electricity supply and then remove the cover
  2. Make sure the water supply pipe is not blocked or air locked
  3. Open the bleed screw on the pump unit by rotating two revolutions

The full answer, free

  • 1 more check in order
  • How to put it right, step by step
  • The manual page for this fault (page 26), right under the answer

Safety: Isolate at the double pole isolator and the consumer unit, and prove dead before the cover comes off. Electrical work to BS 7671 (UK) or I.S. 10101 (Ireland).

From the Triton manual for the T90SR. Check the model on the data plate before you order parts.