Triton T90ER fault 6

Shower performance drops, indicated by a gradual reduction in water flow

Electric shower

What it means

Gradual reduction in water flow caused by water starvation to the unit.

Likely causes

  1. Blocked filter
  2. Blocked or air locked water supply pipe
  3. Water starvation to the unit

Where to start

  1. Isolate the electricity supply and then remove the cover to check the filter is not blocked
  2. Make sure the water supply pipe is not blocked or air locked

The full answer, free

  • How to put it right, step by step
  • The manual page for this fault (page 24), right under the answer

Safety: Isolate at the double pole isolator and the consumer unit, and prove dead before the cover comes off. Electrical work to BS 7671 (UK) or I.S. 10101 (Ireland).

From the Triton manual for the T90ER. Check the model on the data plate before you order parts.