Rinnai A-series continous flow fault 11

Ignition failure

Appliance
Free account: 25 more checks, the readings and the manual page (page 36). No card needed.See the full 11 answer

What it means

Ignition failure after repeated attempts (ignition failure is less than 2 times leads to retry, this code appears after failure sequence).

Likely causes

  1. Gas turned off at water heater
  2. Gas turned off at gas meter or cylinder
  3. Ignition failure is less than 2 times (retry triggered)
  4. Flame not detected after ignition attempts
  5. Flame failure (current less than 1mA)
  6. Repeated flame failure

Where to start

  1. Check current fuse on PCB is normal; if not, flashing code 14 indicates fault and water flow control device full close
  2. Check overheat switch is normal
  3. Check water flow control device full open