Joule Ben Dual Air fault 33031
Low evaporating pressure
Heat pumpFree account: 3 more checks and the manual page (page 36). No card needed.See the full 33031 answer
What it means
Lockout. BEN shuts down for 30 minutes, then attempts to restart.
Likely causes
- Rapid icing at low airflow
- Very low evaporation temperature due to defective expansion valve
- Refrigerant leak
- Ice formation on the evaporator at low outdoor temperatures
Where to start
- Check the airflow
- Clean the evaporator
- Check the expansion valve
The full answer, free
- 3 more checks in order
- How to put it right, step by step
- The manual page for this fault (page 36), right under the answer
Safety: Isolate the heat pump and any backup heater, and give any inverter capacitors time to discharge before you open the electrics. Anything on the refrigerant circuit needs F-gas certification.
Full 33031 fix, readings and manual page. Free.See the full answer
From the Joule manual for the Ben Dual Air. Check the model on the data plate before you order parts.