Hitachi Yutaki M & Yutaki S fault 62
Central mismatch
Heat pumpWhat it means
Triggered in case YUTAKI CASCADE CONTROLLER is configured and they are received central messages, or central control is configured and they are received messages from YUTAKI CASCADE CONTROLLER. In case this alarm appears, software stops Indoor and Outdoor operations until system is properly configured. Option configurable from unit controller - displayed if system has been configured.
Likely causes
- Loose, disconnected, broken or short-circuited connector
- Configuration mismatch between cascade controller and central control
Where to start
- Check system configuration for cascade vs central control conflicts
- Check connector/wiring for faults
- Access Menu > Operation Information to view General system data: operation status, water setting temperature, outdoor ambient temperature, outdoor ambient 2 temperature, outdoor ambient average temperature, second ambient average temperature, 24h average temperature.
The full answer, free
- 7 more checks in order
- How to put it right, step by step
- The manual page for this fault (page 330), right under the answer
Safety: Isolate the outdoor unit and any backup heater, and give the inverter capacitors time to discharge before you open the electrics. Anything on the refrigerant circuit needs F-gas certification.
From the Hitachi manual for the Yutaki M & Yutaki S. Check the model on the data plate before you order parts.
Other Hitachi Yutaki M & Yutaki S fault codes
- 03Lost communication with all sub YUTAKI units
- 10Indoor 2nd DHW thermistor anomaly
- 100Indoor-LCD compressor protection
- 106Excessively high discharge gas temperature
- 12Indoor water outlet thermistor abnormally (THMwo)
- 15Water circuit 2 thermistor abnormally (THMwo2)
- 16Water DHW thermistor abnormally (THMdhwt)
- 17Auxiliary sensor 2 thermistor abnormally (THMaux2)
- 18Auxiliary sensor 1 thermistor abnormally (THMaux1)
- 19Activation of the protection device for the indoor fan motor
- 2Activation of protection device (high pressure cut)
- 203Sub PC-ARFH2E stops answering to main PC-ARFH2E
- 204Indoor unit stops answering to main PC-ARFH2E
- 209Sub DHW configured on unexisting module
- 21XModule X is in alarm state (sub unit)
- 22Thermistor for outdoor ambient temperature (THM7)
- 25Auxiliary sensor 3 thermistor abnormally (THMaux3)
- 3Abnormal transmission between outdoor and indoor units
- 31Incorrect capacity setting or combined capacity between outdoor and indoor units
- 35Incorrect indoor unit number setting
- 38Abnormality of picking up circuit for protection (outdoor unit)
- 4Abnormal transmission between inverter PCB and RASC unit PCB
- 40Incorrect LCD setting
- 48Activation of overcurrent protection