Hitachi Yutaki M & Yutaki S fault 61
No YCC messages received for more than 180 seconds
Heat pumpWhat it means
Communication alarm triggered when no YCC messages have been received for more than 180 seconds since the last message. When triggered, software stops indoor and outdoor operations until communication is restored.
Likely causes
- Loose, disconnected, broken or short-circuited connector
- YCC stops sending messages to slave unit since YCC has been powered OFF or disconnected from the H-Link Line
- H-Link line has been damaged
Where to start
- Check cascade communication wiring and connectors between units
- Verify communication is restored
- Check YCC power status
The full answer, free
- 1 more check in order
- The readings and component tests from the manual
- How to put it right, step by step
- The manual page for this fault (page 334), right under the answer
Safety: Isolate the outdoor unit and any backup heater, and give the inverter capacitors time to discharge before you open the electrics. Anything on the refrigerant circuit needs F-gas certification.
From the Hitachi manual for the Yutaki M & Yutaki S. Check the model on the data plate before you order parts.
Other Hitachi Yutaki M & Yutaki S fault codes
- 03Lost communication with all sub YUTAKI units
- 10Indoor 2nd DHW thermistor anomaly
- 100Indoor-LCD compressor protection
- 106Excessively high discharge gas temperature
- 12Indoor water outlet thermistor abnormally (THMwo)
- 15Water circuit 2 thermistor abnormally (THMwo2)
- 16Water DHW thermistor abnormally (THMdhwt)
- 17Auxiliary sensor 2 thermistor abnormally (THMaux2)
- 18Auxiliary sensor 1 thermistor abnormally (THMaux1)
- 19Activation of the protection device for the indoor fan motor
- 2Activation of protection device (high pressure cut)
- 203Sub PC-ARFH2E stops answering to main PC-ARFH2E
- 204Indoor unit stops answering to main PC-ARFH2E
- 209Sub DHW configured on unexisting module
- 21XModule X is in alarm state (sub unit)
- 22Thermistor for outdoor ambient temperature (THM7)
- 25Auxiliary sensor 3 thermistor abnormally (THMaux3)
- 3Abnormal transmission between outdoor and indoor units
- 31Incorrect capacity setting or combined capacity between outdoor and indoor units
- 35Incorrect indoor unit number setting
- 38Abnormality of picking up circuit for protection (outdoor unit)
- 4Abnormal transmission between inverter PCB and RASC unit PCB
- 40Incorrect LCD setting
- 48Activation of overcurrent protection