Daikin Altherma fault U0-00

Outdoor unit: shortage of refrigerant

Heat pump

What it means

Refrigerant shortage detected in the outdoor unit refrigerant circuit; unit will stop operating.

Likely causes

  1. Faulty refrigerant side thermistor(s)
  2. Faulty refrigerant pressure sensor
  3. Closed stop valve in the refrigerant circuit
  4. Clogged refrigerant circuit
  5. Refrigerant shortage
  6. Non-condensables and/or humidity in the refrigerant circuit
  7. Faulty compressor or miswiring of the compressor power supply cable
  8. Faulty expansion valve
  9. Leak in the refrigerant circuit
  10. Incorrect refrigerant charge
  11. Faulty suction thermistor
  12. Blockages in refrigerant circuit
  13. Poor water flow through high pressure side plate heat exchanger
  14. High pressure switch confirmed faulty during checking procedure

Where to start

  1. Perform a check of all refrigerant side thermistors
  2. Perform a check of the refrigerant pressure sensor
  3. Check that all stop valves of the refrigerant circuit are open

The full answer, free

  • 26 more checks in order
  • The readings and component tests from the manual
  • How to put it right, step by step
  • The manual page for this fault (page 58), right under the answer

Safety: Isolate the outdoor unit and any backup heater, and give the inverter capacitors time to discharge before you open the electrics. Anything on the refrigerant circuit needs F-gas certification.

From the Daikin manual for the Altherma. Check the model on the data plate before you order parts.