Daikin Altherma fault E5-00
Outdoor unit: overheat of inverter compressor motor
Heat pumpWhat it means
Compressor overload is detected.
Likely causes
- Closed stop valve in the refrigerant circuit
- Faulty discharge pipe thermistor or connector fault
- Faulty outdoor unit fan motor
- Faulty compressor or miswiring of the compressor power supply cable
- Faulty expansion valve
- Faulty 4-way valve
- Faulty refrigerant pressure sensor
- Poor water flow through high pressure side plate heat exchanger
- Incorrect refrigerant charge
- Bad contact between refrigerant loop and inverter heat sink
- Lack of refrigerant
- Faulty suction thermistor
- Blockages in refrigerant circuit
- Worn or damaged compressor dampers causing vibration/noise
- Compressor guard timer active
- Normal inverter control behavior when target temperature achieved
- Water pump software control behaviour based on setting [F-0D]
- Special software control activated - water loop temperature is too low causing ONLY the backup heater to operate
- Faulty compressor winding
- High pressure switch confirmed faulty during checking procedure
- Flammable refrigerant remaining dissolved in compressor lubricant
- Wrong assembly during repair
- Excessive heat applied during brazing near compressor pipes
Where to start
- Check that all stop valves of the refrigerant circuit are open
- Perform a check of the discharge pipe thermistor
- Perform a check of the outdoor unit fan motor
The full answer, free
- 44 more checks in order
- The readings and component tests from the manual
- How to put it right, step by step
- The manual page for this fault (page 37), right under the answer
Safety: Isolate the outdoor unit and any backup heater, and give the inverter capacitors time to discharge before you open the electrics. Anything on the refrigerant circuit needs F-gas certification.
From the Daikin manual for the Altherma. Check the model on the data plate before you order parts.
Other Daikin Altherma fault codes
- 4-02Incorrect setting of space heating OFF temperature
- 7HFlow error (minimum flow rate not reached)
- 7H-01Water flow problem
- 7H-04Water flow problem during domestic hot water production
- 7H-05Water flow problem during heating/sampling
- 7H-06Water flow during cooling/defrost
- 7H-07Water flow problem. pump de-blocking active
- 7H-XXWater flow or volume too low
- 80-00Inlet water thermistor abnormality
- 81-00Outlet water thermistor abnormality
- 81-01Mixed water thermistor abnormality
- 89-01Heat exchanger frozen
- 89-02Heat exchanger frozen
- 89-03Heat exchanger frozen
- 8F-00Abnormal increase outlet water temperature (domestic hot water)
- 8H-00Abnormal increase outlet water temperature
- 8H-01Overheating mixed water circuit
- 8H-02Overheating mixed water circuit (thermostat)
- 8H-03Safety thermostat circuit open with jumper removed
- A1-00Zero cross detection problem
- A5-00Outdoor unit: high pressure peak cut / freeze protection problem
- AA-01Backup heater overheated
- AA-02External backup heater overheated
- AC-00Booster heater overheated